OpManager Plus Enterprise Edition Installation

OpManager Plus Enterprise Edition can be deployed in cases when geographically distributed networks need to be monitored from a central location, or if there is a need to monitor more than 1k devices.

ManageEngine recommends the installation of OpManager Plus Central server and a Probe to effectively achieve a distributed network monitoring environment.

.

Central Server: Central periodically monitors health, performance and fault data across all Probes and consolidates the information in one location.

Probe Server: The Probe periodically polls the devices in the local network and updates data to the central server. The probe can be installed at the Remote Location.

Note:If OpManager Plus has an MSSQL server as the backend database, then it must be configured first, before proceeding with the following installation. 

Installing OpManager Plus Enterprise Edition on Windows

OpManager Plus Central Server

Step 1: Download the OpManager Plus Central.exe from this link: Download Central Server | ManageEngine OpManager Plus

Run the exe as 'administrator'.

Step 2: Click 'Next' to proceed with installation.

Step 3: Click 'Yes' to the OpManager Plus License agreement.

Step 4: Choose the destination folder for OpManager Plus installation and click 'Next' to proceed.

Step 5: If you want to change the default web server port for OpManager Plus installation enter the new port number (OpManager Plus central uses 8060 as the default web server port) and click 'Next' to proceed.

Step 6: Register for technical support by providing your contact information such as Name, E-mail ID, etc., and click 'Next'.

Step 7: If you select PGSQL, please proceed with Step 10. (or) If you select 'MSSQL' database (recommended for production). Click 'Next' to proceed.

Step 8: If you select SQL Authentication, then provide MSSQL details like Host Name, Port, Database Name. 

Step 9: Use the SQL Server Authentication credentials (Username and Password) created earlier. Click 'Next' to proceed

(or)

If you select WINDOWS Authentication, then provide MSSQL details like Host Name, Port, Domain Name, Database Name, Username and Password. Click 'Next' to proceed.

Step 10: Search for 'bcp.exe' file click 'Next' to proceed.

Note: The SQL server version compliant with the SQL Native Client must be installed in the same Server.

Step 11: Click 'Finish' to complete OpManager Plus Central Server installation.

OpManager Plus Probe Server

Step 1: Download the OpManager Plus Probe.exe from the below link: Download Probe Server | ManageEngine OpManager Plus (OR) Open OpManager Plus Central and you will view a welcome notification screen with the Probe download link button. (The Probe installation key will get refreshed automatically every fifteen minutes. You can also use the refresh button to manually refresh the key.)

Run the exe as 'administrator' or Open the installed webclient and click on Probe Link Download to download the appropriate Probe installer. Please ensure that the central and the probe are the same version

Step 2: Click 'Next' to proceed with installation.

Step 3: Click 'Yes' to the OpManager Plus Probe License agreement

Step 4: Choose the destination folder for OpManager Plus Probe installation and click 'Next' to proceed.

Step 5: OpManager Plus uses 8060 as the default web server port, change it as per your preference and click 'Next' to proceed.

Step 6: Register your OpManager Plus license with required details to get technical support and click 'Next' to proceed.

Step 7: Enter the details of the proxy server if you want to use a proxy to communicate with the Central. If you do not need a proxy, please click Next without filling the details.

Step 8: If you select PGSQL, please proceed with Step 12. (or) If you select 'MSSQL' database (recommended for production). Click 'Next' to proceed and choose the authentication type - Windows/SQL.

Step 9: Provide MSSQL details like host name, port, database name. Use the credentials (username and password) that was created earlier while configuring SQL. Click 'Next' to proceed.

Step 10: Search for bcp.exe file and select it. Click 'Register' to proceed.

Step 11: Provide OpManager Plus Central server details like central server URL, Probe Name, Contact Name and Contact Mail ID.
Enter the Probe installation key. You can find the Probe Installation key in the Central Server page under Settings->Configuration->Probe Details.

Step 12: Click 'Finish' to complete OpManager Plus Probe installation. 

Note: You can also navigate to the Probe details page in the Central server to access the Probe download link.

Installing OpManager Plus Enterprise Edition on Linux

Prerequisites

  1. Sometimes, you might encounter errors such as database connection not getting established or the server not starting up. To workaround these issues, comment the IPv6 related entries in the /etc/hosts file.
  2. Check if the DNS resolves properly to the IP Address on the system in which OpManager Plus is installed. Add an entry to /etc/host file with ipaddress and host name if there is trouble starting OpManager. 

Central Server

Step 1: Download ManageEngine_OpManager_Plus_Central_64bit.bin for Linux.

Step 2: Login as root user.

Step 3: Assign the executable permission to the downloaded file using the following command: chmod a+x ManageEngine_OpManager_Plus_Central_64bit.bin.

Step 4: Execute ./ManageEngine_OpManager_Plus_Central_64bit.bin with administator/root privileges (sudo). This will display the installation wizard.

Step 5: Click 'Next' to begin the installation process. Go through the license agreement and proceed to the next step.

Step 6: In the subsequent steps of the wizard, select the OpManagerPlusCentral language, the directory to install OpManagerPlusCentral, and the port number to run OpManagerPlusCentral Web Server. Proceed to the next step.

Step 7: Verify the installation details and click 'Next'.<

Step 8: Click 'Finish' to complete the installation process.

Note: It is recommended to install OpManagerPlusCentral in the opt folder. By default, OpManagerPlusCentral is installed in the /opt/ManageEngine/OpManagerPlus_Central directory. 

Probe Server

Step 1: Download ManageEngine_OpManager_Probe_64bit.bin for Linux.

Step 2: Login as root user.

Step 3: Assign the executable permission to the downloaded file using the following command: chmod a+x ManageEngine_OpManager_Probe_64bit.bin

Step 4: Execute ./ManageEngine_OpManager_Probe_64bit.bin with administator/root privileges (sudo). This will display the installation wizard.

Step 5: Click 'Next' to begin the installation process. Go through the license agreement and proceed to the next step.

Step 6: In the subsequent steps of the wizard, select the OpManagerPlusProbe language, the directory to install OpManagerPlusProbe, and the port number to run the OpManagerPlusProbe Web Server. Proceed to the next step.

Step 7: Please enter the Central URL, Probe Name, Probe Installation Key, Username, Email ID and proceed to register the Probe.

Step 8: Verify the installation details and click 'Next'.

Step 9: Click 'Finish' to complete the installation process.

Note: It is recommended to install OpManagerPlusProbe in the opt folder. By default, OpManagerPlusProbe is installed in the /opt/ManageEngine/OpManagerProbe directory.

Installing OpManager Plus Enterprise Edition on Linux using Console mode/ Silent mode

Prerequisites

To begin with, make sure you have downloaded the binary for Central and Probe for Linux OS.

Click here to download the binary files for OpManager plus Central and Probe (Linux OS). 

Central Server

Step 1: Execute ManageEngine_OpManager_Central_64bit.bin with administrator privileges (sudo) and -i console option.

Step 2: Go through the license agreement and enter 'Y' to proceed. You can register for technical support by providing the required details. (Name, E-mail ID, Phone, Company Name)

Step 3: Select the location.

Step 4: Choose the installation directory.



Step 5: Configure the Webserver Port. (The default webserver port is 8060.)

Step 6: Verify the installation details and press 'Enter' to complete the installation.

Probe Server

Step 1: Execute ManageEngine_OpManager_Plus_Probe_64bit.bin with security privileges (sudo) and -i console option.



Step 2: Go through the license agreement and enter 'Y' to proceed. You can register for technical support by providing the required details. (Name, E-mail ID, Phone, Company Name).

Step 3: Select the location from the list of available countries.

Step 4: Choose the installation directory and configure the Webserver Port.

 

Step 5: Verify the installation details and the installation status.

Step 6: Configure the Probe details and press 'Enter' to complete the installation.

Starting OpManager Plus Enterprise Edition on Linux

  • Go to /OpManager/bin folder.
  • Execute: sh run.sh.
  • To run OpManager Plus server in the background, execute: nohup sh run.sh&