The Cisco Unified Computing System (CISCO UCS) is a next-generation data center platform that unites compute, network, storage access, and virtualization into a cohesive system designed to reduce total cost of ownership (TCO) and increase business agility.
Applications Manager offers monitoring for Cisco UCS environments, where you can monitor and track various KPIs of the applications and the system. It collects real-time Cisco UCS's data to present it in a dashboard that is easy to understand and helps you to identify the reason why your system has deviated from the ideal performance.
Follow the steps given below to create a new Cisco UCS monitor:
Go to the Monitors Category View by clicking the Monitors tab. Click on Cisco UCS under the Converged Infrastructure table. Displayed is the Cisco UCS bulk configuration view distributed into three tabs:
On clicking a monitor from the list, you'll be taken to the Cisco UCS monitor dashboard. It has 9 tabs -
This tab provides details about the overall count of all the components present in the UCS system.
Parameter | Description |
---|---|
Server Response Time: | |
Response time | The response time of the Cisco UCS Manager. (ms) |
Components: | |
Total number of Chassis Servers | The total number of Chassis servers in the UCS system. |
Total number of Rack Mount Servers | The total number of Rack Mount servers in the UCS system. |
Total number of Fabric Extenders | The total number of fabric extenders in the UCS system. |
Total number of Fabric Interconnects | The total number of fabric interconnects in the UCS system. |
Total number of Processor Units | The total number of processor units in the UCS system. |
Total number of Adaptor Units | The total number of adaptor units in the UCS system. |
Total number of I/O Modules | The total number of input-output modules in the UCS system. |
This tab provides details about the performance metrics of various chassis available in the UCS system.
Parameter | Description |
---|---|
Chassis: | |
Chassis Name | The name of the chassis. |
Chassis Server Count | The number of Chassis servers present in the chassis. |
I/O Module Count | The number of input-output modules present in the chassis. |
Fan Count | The number of fans available in the chassis. |
Power Unit Count | The number of power units (PSU) available for the chassis. |
Chassis Operational Status | The operational status of the chassis. ( Operable / Degraded ) |
Chassis Server: | |
Name | The name of the blade server. |
Chassis Name | The name of the chassis. |
Model | The model name of the blade server. |
Operablility | Denotes the operability condition of the blade server. |
Power | The power state of the blade server. (On / Off) |
Adaptor count | The number of adaptors available. |
Network Interface Cards | The number of Network Interface Cards present. |
Memory and CPU: | |
Name | The name of the blade server. |
Chassis Name | The name of the chassis. |
Core count | The number of CPU cores available. |
Core Enabled | The number of CPU cores that are enabled. |
CPU count | The number of CPUs available. |
Thread count | The total number of threads available in the CPUs. |
Available Memory | The amount of memory available in the server. (GB) |
Total Memory | The total amount of memory allocated to the server. (GB) |
Available Memory % | The amount of memory available in the server. (%) |
Utilized Memory % | The amount of memory utilized by the server. (%) |
Motherboard Power: | |
Name | The name of the blade server. |
Chassis Name | The name of the chassis. |
Power Consumed | The amount of power currently being consumed by the motherboard. ( Watts ) |
Max Power Consumed | The maximum amount of power consumed by the motherboard. ( Watts ) |
Min Power Consumed | The minimum amount of power consumed by the motherboard. ( Watts ) |
Input Current | The amount of input current flowing to the motherboard currently. ( Ampere ) |
Max Input Current | The maximum amount of input current received by the motherboard. ( Ampere ) |
Min Input Current | The minimum amount of input current received by the motherboard. ( Ampere ) |
Input Voltage | The amount of input voltage currently being fed to the motherboard. ( Voltage ) |
Max Input Voltage | The maximum amount of voltage received by the motherboard. ( Voltage ) |
Min Input Voltage | The minimum amount of voltage received by the motherboard. ( Voltage ) |
Motherboard Temperature: | |
Name | The name of the blade server. |
Chassis Name | The name of the chassis. |
Front Temperature | The temperature value indicated by the front-panel temperature sensor. ( Celsius ) |
Rear Temperature | The temperature value indicated by the rear-panel temperature sensor. ( Celsius ) |
Rear Temperature Left | The temperature value indicated by the left rear-panel temperature sensor. ( Celsius ) |
This tab provides details about the performance metrics of various rack mount servers available in the UCS system.
Parameter | Description |
---|---|
Rack Mount Server: | |
Name | The name of the blade server. |
Model | The model name of the rack server. |
Operability | Denotes the operational condition of the blade server. |
Power | The power state of the blade server. (On / Off) |
Adaptor count | The number of adaptors available. |
Network Interface Cards | The number of Network Interface Cards available. |
Memory and CPU: | |
Name | The name of the rack server. |
Core Count | The number of CPU cores available. |
Core Enabled | The number of CPU cores enabled. |
CPU Count | The number of CPUs available. |
Thread Count | The total number of threads available in the CPUs. |
Available Memory | The amount of memory available in the server. (GB) |
Total Memory | The total amount of memory allocated to the server. (GB) |
Available Memory % | The amount of memory available in the server. (%) |
Utilized Memory % | The amount of memory utilized by the server. (%) |
Motherboard Power: | |
Name | The name of the rack server. |
Power Consumed | The amount of power currently being consumed by the motherboard. ( Watts ) |
Max Power Consumed | The maximum amount of power consumed by the motherboard. ( Watts ) |
Min Power Consumed | The minimum amount of power consumed by the motherboard. ( Watts ) |
Input Current | The amount of input current flowing to the motherboard currently. ( Ampere ) |
Max Input Current | The maximum amount of input current received by the motherboard. ( Ampere ) |
Min Input Current | The minimum amount of input current received by the motherboard. ( Ampere ) |
Input Voltage | The amount of input voltage currently being fed to the motherboard. ( Voltage ) |
Max Input Voltage | The maximum amount of voltage received by the motherboard. ( Voltage ) |
Min Input Voltage | The minimum amount of voltage received by the motherboard. ( Voltage ) |
Motherboard Temperature: | |
Name | The name of the rack server. |
Front Temperature | The temperature value indicated by the front- panel temperature sensor. ( Celsius ) |
Rear Temperature | The temperature value indicated by the rear - panel temperature sensor. ( Celsius ) |
Ambient Temperature | The ambient temperature value of the motherboard. ( Celsius ) |
IO Hub1 Temperature Right | The temperature value of I/O Hub1. ( Celsius ) |
IO Hub2 Temperature Right | The temperature value of I/O Hub2. ( Celsius ) |
This tab provides details about the performance metrics of various Fabric Interconnects available in the UCS system.
Parameter | Description |
---|---|
Fabric Interconnect: | |
Name | The name of the Fabric Interconnect ( FI ). |
Fan | The number of fans associated with the FI. |
Power Supply Unit Count | The number of Power Supply Units (PSU) available in the FI. |
Fabric Interconnect Software: | |
Name | Name of the Fabric interconnect ( FI ) |
Available Memory | The amount of memory available in the server. (GB) |
Total Memory | The total amount of memory allocated to the server. (GB) |
Cached Memory | The amount of cached memory of the server. (GB) |
Available Memory % | The amount of memory available in the server. (%) |
CPU utilization % | The current CPU utilization of the server. (%) |
Fabric Interconnect Power Unit (PSU): | |
Name | The name of the PSU. |
Fabric Interconnect | The name of the Fabric Interconnect ( FI ). |
Power Consumed | The amount of power currently being consumed by the PSU. ( Watts ) |
Max Power Consumed | The maximum amount of power consumed by the PSU. ( Watts ) |
Min Power Consumed | The minimum amount of power consumed by the PSU. ( Watts ) |
Input Current | The amount of input current flowing to the PSU currently. ( Ampere ) |
Max Input Current | The maximum amount of input current received by the PSU. ( Ampere ) |
Min Input Current | The minimum amount of input current received by the PSU. ( Ampere ) |
Input Voltage | The amount of input voltage currently being fed to the PSU. ( Voltage ) |
Max Input Voltage | The maximum amount of voltage received by the PSU. ( Voltage ) |
Min Input Voltage | The minimum amount voltage received by the PSU. ( Voltage ) |
Fabric Extender: | |
Name | The name of the Fabric Extender ( FEX ). |
Fan | The number of fans associated with the FEX. |
I/O Module | The number of I/O modules present in the FEX. |
Power Supply Unit Count | The number of Power Supply Units (PSU) present in the FEX. |
This tab provides details about the performance metrics of various processors available in the UCS system.
Parameter | Description |
---|---|
Processors | |
Name | The name of the processor. |
Equipment | The equipment at which the processor is present. |
Model | The model name of the processor. |
Speed | The speed of the processor. |
Core Count | The number of cores available. |
Core Enabled | The number of cores enabled. |
Thread Count | The number of threads available. |
CPU Temperature | The current temperature value of the CPU. |
CPU Input current | The current input current value of the CPU. |
This tab provides details about the performance metrics of various fans available in the UCS system.
Parameter | Description |
---|---|
Fan Module: | |
Name | The name of the fan module. |
Equipment | The equipment at which the fan module is present. |
Fans | The number of fans available in the module. |
Thermal Condition | The thermal condition of the fan module. |
Fan Module Power | The power state of the fan module. (On/Off) |
Fan Module Operability | Denotes the operability of the fan module. |
Fans: | |
Name | The name of the fan. |
Fan Module | The name of the fan module. |
Equipment | The equipment at which the fan module is present. |
Model | The model name of the fan. |
Thermal Condition | The thermal condition of the fan. |
Fan Power | The power state of the fan. (On/Off) |
Fan Operability | Denotes the operability of the fan. |
Drive Percentage | The drive performance of the fan. (%) |
Speed | The speed of the fan. (RPM) |
Max Speed | The maximum speed of the fan. (RPM) |
Min Speed | The minimum speed of the fan. (RPM) |
This tab provides details about the performance metrics of various I/O modules available in the UCS system.
Parameter | Description |
---|---|
I/O Module: | |
Name | The name of the I/O module. |
Equipment | The equipment at which the I/O module is present. |
Model | The model name of the I/O module. |
Thermal Condition | The thermal condition of the I/O module. |
Operability | Denotes the operability of the I/O module. |
This tab provides details about the performance metrics of various ports available in the UCS system.
Parameter | Description |
---|---|
Ethernet ports: | |
Name | The name of the Ethernet port. |
Equipment | The equipment at which the Ethernet port is present. |
Mac Address | The MAC address of the Ethernet port. |
Interface Role | The interface role of the Ethernet port. |
Interface Type | The interface type of the Ethernet port. |
Ethernet port status | The operability status of the Ethernet port. |
Ethernet Admin State | The admin state of the Ethernet port. |
Slot ID | The slot ID associated with the Ethernet port. |
Operational Speed | The operational speed of the Ethernet port. |
Backplane ports: | |
Name | The name of the backplane port. |
Equipment | The equipment at which the backplane port is present. |
Slot ID | The slot ID associated with the backplane port. |
Mac Address | The MAC address of the backplane port. |
Interface Role | The interface role of the backplane port. |
Interface Type | The interface type of the backplane port. |
BackPlane Port status | The operability status of the backplane port. |
BackPlane Admin State | The admin state of the backplane port. |
Fabric ports: | |
Name | The name of the fabric port. |
Equipment | The equipment at which the fabric port is present. |
Slot ID | The slot ID associated with the fabric port. |
Mac Address | The MAC address of the fabric port. |
Interface Role | The interface role of the fabric port. |
Interface Type | The interface type of the fabric port. |
Fabric Port status | The operability status of the fabric port. |
Fabric Admin State | The admin state of the fabric port. |
This tab provides details about the faults that are available in the UCS system.
Parameter | Description |
---|---|
Fault Statistics: | |
Critical Faults | The number of faults that are of Critical severity. |
Major Faults | The number of faults that are of Major severity. |
Minor Faults | The number of faults that are of Minor severity. |
Warning Faults | The number of faults that are of Warning severity. |
Faults between consecutive polls: | |
Fault Code | The fault code which describes the fault. |
Fault Id | The ID of the fault occurred. |
Type | The severity type of the fault occurred. (Critical/Major/Minor/Warning) |
Fault Affected object | The hardware object that was affected by the fault. |
Fault Cause | The cause for the fault to occur. |
Fault Created Time | The time at which the fault was created. |
Last transition Time | The time at which the state of fault was changed. |
Fault Description | The description of the fault occurred. |
Show All Faults | Displays all the faults that are currently present in the system. |